Operating Conditions
The performance and life of the pick-up medium, wiper blades, pulleys, etc. are affected by operating conditions. These include temperatures in and out of the liquid, the pH of the solution and the presence of solvents or other reactive chemicals.
Hazardous Materials
Applications involving flammable materials or explosive vapors require the use of explosion-proof (or air-driven) motors and controls.
Temperature/Viscosity
All skimmers require floating oil to be in a liquid, free-flowing state. (See Note 2 under Table 1 for an exception.) If the oil congeals or solidifies at ambient temperatures, the reservoir and/or skimmer will require heaters to maintain fluid flow.
Skimmed Water Content
All oil skimmers pick up some water with the oil. Suction skimmers pick up more water than other types. High water content increases oil recycling and disposal costs. Generally, the ratio of water to oil decreases with thicker films of floating oil and slower moving pick-up media. A concentrator or decanter installed at the skimmer discharge port provides secondary oil/water separation that can reduce water content to nearly zero.
Residual Oil
Portability
In some plants mobile equipment service shops and at remediation sites, a portable skimmer can sometimes service multiple machines, sumps or wells.
Tank or Sump Characteristics
The location, shape and capacity of a tank or water impoundment are major factors in choosing the right skimmer. Also consider fluctuations in water level, turbulence and possible emulsions. Although skimmers do not cause emulsions, they may have trouble removing certain types.
Size/Design
Oil and water can emulsify when subjected to turbulence and other mechanical agitation. Avoid this by having water return to the tank below the liquid surface at as low a velocity as practical. Make sure the tank or sump provides quiet areas, weirs and sufficient volume to allow adequate time for oil/water separation.
Shape
Location/Installation
Questions to ask about the physical location and characteristics of the tank and collection container: Does skimmed material need to be pumped from the skimmer to the container? Will skimmer access for periodic maintenance be a problem? How much mounting space is available? Are tank or container modifications required? (Total skimmer system costs may involve additional components, tank modifications and skimmer maintenance.)
All of our coolant skimmers are rugged, reliable and low maintenance. Removal capacities range from 1 to 200 gallons per hour. Browse the types of oil skimmers and oil skimming accessories in our website www.abanaki.com or contact our experts at 440-543-7400 to find the right solution for your application.